污水处理设备 污泥处理设备 水处理过滤器 软化水设备/除盐设备 纯净水设备 消毒设备|加药设备 供水/储水/集水/排水/辅助 水处理膜 过滤器滤芯 水处理滤料 水处理剂 水处理填料
恩德斯豪斯(中国)
产品规格参数测量误差Volumeflow(standard):±0
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
9 dm³/min to 162 000 m³/h (2.5 gal/min to 100 000 gal/min)
Liner material polyamide: 0 to +60°C (+32 to +140°F)
PN 40, Class 300, 20K
Liner material polyamide: 0 to +60°C (+32 to +140°F)
Electrodes: 1.4435 (316L)
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
9 dm³/min to 162 000 m³/h (2.5 gal/min to 100 000 gal/min)
Liner material polyamide: 0 to +60°C (+32 to +140°F)
PN 40, Class 300, 20K
Liner material polyamide: 0 to +60°C (+32 to +140°F)
Electrodes: 1.4435 (316L)
电磁
Highly cost-effective wafer flowmeter with easy-to-use operation concept.
For basic water applications, optimized for limited space and plastic pipe installations.
Easy, fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Short face-to-face length and low weight. Integrated ground disks made of stainless steel. International drinking water approvals.
Optimum usability – operation with devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
2-line display with push buttons. Device as compact or remote version. HART.
DN 25 to 100 (1 to 4")
Liner material polyamide: 0 to +60°C (+32 to +140°F)
Electrodes: 1.4435 (316L)
Volume flow, conductivity, mass flow
Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
9 dm³/min to 162 000 m³/h (2.5 gal/min to 100 000 gal/min)
PN 40, Class 300, 20K
Liner material polyamide: 0 to +60°C (+32 to +140°F)
-40 to 60°C (-40 to 140°F)
DN 25 to 100 (1 to 12"): AlSi10Mg, coated
Polycarbonat; AlSi10Mg, coated
Compact version: IP66/67, type 4X enclosure
Sensor remote version (standard): IP66/67, type 4X enclosure
LCD display with touch & auto rotate
4-20 mA HART (active/passive), Pulse/frequency/switch output
Modbus RS485, 4-20 mA
HART, MODBUS RS485
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
CSA, GP
产品安全性
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
卫生型认证和证书