WIKA PGS23.100 switchGAUGE 不锈钢带开关触点耐震电接点压力表

详细介绍

 

类型: 电接点压力表 型号: PGS23.100 PGS23.160
联接型式: G1/2 精度等级: 1.0
品牌: WIKA/威卡 环境温度: -40-70(℃)
加工定制: 公称直径: 100 160(mm)
测量范围: 0-0.6bar to 0-600bar(MPa)    

WIKA PGS23.100 switchGAUGE

不锈钢带开关触点耐震电接点压力表

 

Bourdon tube pressure gauge with switch contacts
Models PGS23.1x0, stainless steel version


Bourdon tube pressure gauge model PGS23.100 with
switch contact model 831.1


 

    Description
    Wherever the process pressure has to be indicated locally,and, at the same time, circuits are to be made or broken, the model PGS23.1x0 switchGAUGE can be used.
Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
The set pointer can be adjusted using a removable adjustment key in the window.


     Applications
     Control and regulation of industrial processes
     Monitoring of plants and switching of electric circuits
     For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive ambience
     Process industry: Chemical, petrochemical, power plants,mining, on- and offshore, environmental technology, machine building and general plant construction

   Special features
    High reliability and long service life

    Up to 4 switch contacts per instrument
    Also available with liquid-filled case for high dynamic pressure loads or vibrations
    Gauges with inductive contacts for use in hazardous areas with ATEX approval
    Gauges with electronic contact for PLC applications
    Gauges in safety version S3 (k)

   

    Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.
    The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-1) and regulations for the on-site display of the working pressure of pressure vessels.
    As switch contacts magnetic snap-action contacts, reed switches, inductive contacts - for requirements to ATEX - or electronic contacts for triggering a PLC are available.
    For further information on the different switch contacts please see data sheet AC 08.01.

   

   Standard version

    Nominal size in mm
    100, 160

    Accuracy class
    1.0

    Scale ranges
    0 … 0.6 to 0 … 1,600 bar
    or all other equivalent vacuum or combined pressure and vacuum ranges

    Pressure limitation
    Steady:      Full scale value
    Fluctuating: 0.9 x full scale value
    Short time:  1.3 x full scale value

    Permissible temperature
    Ambient: -20 ... +60 °C for gauges without liquid filling and gauges with silicone oil filling
    Medium: +200 °C maximum without liquid filling
            +100 °C maximum with liquid filling

    Temperature effect
    When the temperature of the measuring system deviates from the reference temperature (+20 °C):max. ±0.4 %/10 K of full scale value

    Process connection
    Stainless steel 316L,
    lower mount (LM) or lower back mount (LBM)
    G ½ B (male), 22 mm flats


   Pressure element
    Stainless steel 316L
    < 100 bar: C-type
    ≥ 100 bar: Helical type


   Movement
    Stainless steel
    

   Dial
    Aluminium, white, black lettering

   Pointer
    Instrument pointer: Aluminium, black
    Set pointer: red
 

    Case
    Stainless steel, scale ranges ≤ 0 ... 16 bar with compensating valve to vent case, with blow-out device in case back
    With safety version: With solid baffle wall (Solidfront) and blow-out back, hermetically sealed, with internal pressure compensation
   Window
    Laminated safety glass

   Bezel ring
    Cam ring (bayonet type), stainless steel
   

   Electrical connection
    Terminal box

   Ingress protection
    IP 65 per EN 60529 / IEC 529

 

   Switch contacts
     Magnetic snap-action contact model 821
     No control unit and no extra power supply required
     Direct switching up to 250 V, 1 A
     Up to 4 switch contacts per measuring instrument
    Inductive contact model 831
     Long service life due to non-contact sensor
     Additional control unit required (model 904.xx)
     With corresponding control unit suitable for use in zone 1 /21 (2 GD) hazardous areas
     Low effect on the indication accuracy
     Fail-safe switching at high switching rates
     Insensitive to corrosion
     Up to 3 switch contacts per measuring instrument
    Electronic contact model 830 E
     For direct triggering of a programmable logic controller(PLC)
     2-wire system (option: 3-wire system)
     Long service life due to non-contact sensor
     Low effect on the indication accuracy
     Fail-safe switching at high switching rates
     Insensitive to corrosion
     Up to 3 switch contacts per measuring instrument
    Reed switch model 851
     No control unit and no extra power supply required
     Direct switching up to 250 V, 1 A
     Also suitable for direct triggering of a programmable logic controller (PLC)
     Free from wear as without contact
     Up to two change-over contacts per measuring instrument
    Switching function
     The switching function of the switch is indicated by function index 1, 2 or 3.
     Model 8xx.1: Contact makes (clockwise pointer motion)
     Model 8xx.2: Contact breaks (clockwise pointer motion)
     Models 821.3 and 851.3: Change over; one contact breaks and one contact makes simultaneously when pointer reaches set point
For further information please see data sheet AC 08.01, electrical switch contacts

   

   Options
     Other process connection
     Sealings (model 910.17, see data sheet AC 09.08)
     Liquid filling (observe: With safety version only lower mount)
     Inductive contacts also in safety version (SN, S1N)
     Dual scale
     Panel mounting flange, polished stainless steel
     Surface mounting flange, stainless steel
     Surface mounting lugs on the back, stainless steel (safety version)
     SIL2 approval (safety version)
     Pressure switch per VdTÜV code of practice 100

    

    Dimensions in mm
    switchGAUGE model PGS23.100 with switch contact model 821, 831 or 830 E

   

    switchGAUGE model PGS23.100 (safety version) with switch contact model 821, 831 or 830 E

   

    switchGAUGE model PGS23.160 with switch contact model 821, 831 or 830 E

   

    switchGAUGE model PGS23.160 (safety version) with switch contact model 821, 831 or 830 E

   

   switchGAUGE model PGS23.100 with switch contact model 851.3 or 851.33

  

    switchGAUGE Typ PGS23.100 (safety version) with switch contact model 851.3 or 851.33

   

    switchGAUGE model PGS23.160 with switch contact model 851.3 or 851.33

   

 