行业产品

  • 行业产品

卓尔瑞华(北京)科技有限公司


当前位置:卓尔瑞华(北京)科技有限公司>>WIKA压力及温度仪表>>WIKA DA10 差压开关 高静压保护10bar 低压60mbar EEx-d防爆 IP65

WIKA DA10 差压开关 高静压保护10bar 低压60mbar EEx-d防爆 IP65

返回列表页
参  考  价面议
具体成交价以合同协议为准

产品型号DA10

品       牌

厂商性质代理商

所  在  地北京市

联系方式:仇立新查看联系方式

更新时间:2022-07-12 15:32:45浏览次数:436次

联系我时,请告知来自 环保在线

经营模式:代理商

商铺产品:93条

所在地区:北京北京市

联系人:仇立新 (销售工程师)

产品简介

WIKA DA10 差压开关 高静压保护10bar 低压60mbar EEx-d防爆 IP65

详细介绍

 

类型: 机械压力开关 额定电压: 220(V)
zui大工作压力: 60mbar(Pa) 型号: DA10
额定电流: 15(A) 品牌: WIKA/威卡
机械寿命: 100(万次) 产品认证: CE
加工定制:    

    WIKA DA10 差压开关 高静压保护10bar 低压60mbar EEx-d防爆 IP65

Differential pressure switch
Ex protection Ex-d, IP 65, for low pressure ranges
Model DA10



Differential pressure switch model DA10

 

 

      Applications
       ■ Differential pressure monitoring and direct switching of electrical loads
       ■ For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive ambience
       ■ Process industry: Chemical/petrochemical, on- and offshore, technical gases, environmental technology,machine building and general plant construction, water treatment, pharmaceutical industry
       ■ Pump monitoring and control / filter monitoring, level measurement in closed tanks
       ■ Ignition protection type GAS Ex-d DUST Ex-tD Gr. II Cat. 1/2 GD

 

      Special features
       ■ Case flameproof enclosure
       ■ Ingress protection IP 65, NEMA 4
       ■ Ambient temperature -30 ... +85 °C
       ■ 1 or 2 independent switch points, high contact rating up to 15 A / AC 220 V
       ■ Differential pressure from 16 mbar, working pressure (static pressure) up to 10 bar
 
 
      Description
       These high-quality differential pressure switches have been developed especially for safety-critical applications. The high quality of the products ensures reliable monitoring of your plant. The manufacturer Cella is certified to ISO 9001.In production, the switches are traced by quality assurance software at every step and subsequently are 100 % tested.
      All wetted parts materials are from stainless steel as standard. Each switch family is available in IP 65, Ex-ia or Ex-d versions.

      In order to ensure as flexible operation as possible, the pressure switches are equipped with micro switches, which make it possible to switch an electrical load of up to 15 A / AC 220 V directly. For smaller contact ratings, such as for PLC applications, Argon gas-filled micro switches with gold-plated contacts can be selected as an option.
      By using a diaphragm measuring cell with fulcrum lever transmission, the model DA10 pressure switch is extremely robust and guarantees optimal operating characteristics.

 

 

     

     Switch points
      The switch points can be set to your requirements, free-ofcharge.
      Please specify:

      Switch point, switching direction for each contact (e.g. switch point 1: 0.5 bar, falling, switch point 2: 3 bar, rising)
      With two micro switches, the switch points can be set independently of each other.

 

      After unscrewing the case cover, switch point adjustment can be made using the adjustment screw. The switch point is settable within the entire measuring range with the following
     general rule:
      ■ Define the value A = 2 x repeatability + switch hysteresis
      ■ If the pressure is rising, the switch point should be set between (min. + value A) up to max. of the setting range
      ■ If the pressure is falling, the switch point should be set between min. up to (max. - value A) of the setting range

 

 

     Example:
      Setting range: 0 ... 1 bar with one switch contact
      Repeatability: 1 % of 1 bar = 10 mbar
      Switch hysteresis = 15 mbar (see table setting ranges)
      Value A = 2 x 10 mbar + 15 mbar = 35 mbar
      If the pressure is rising, the switch point should be set between 35 mbar up to 1 bar.
      If the pressure is falling, the switch point should be set between 0 up to 965 mbar.
      For optimal performance we suggest the switch point lies between 25 % and 75 % of the setting range.

     Electrical connection
      ½ NPT female, cable connection using internal terminal block, protective conductor connection using internal and external screw, max. earth cable cross-section 4 mm2

 

     Pressure switch certified per:
      ■ Pressure equipment directive 97/23/EC (PED, annex 1, category IV, safety accessories, module B + D)
      ■ Low voltage directive 73/23 EEC and 93/68 EEC

  

 

     Dielectric strength
      Safety class I (EN 61298-2: 1997-06)

 

     Mounting
      Direct or wall mounting
      Preferred connection location of the process connection should be below.

 

     Weight
      approx. 10 kg

 

     Options
      ■ Other process connection, also with adapter
      ■ Sealings (model 910.17, see data sheet AC 09.08)
      ■ Electrical connection 3/4 NPT, G 1/2, G 3/4 or M20 x 1.5 (female)
      ■ Cable gland on request
      ■ 2" pipe-mounting kit (with clamping element)
      ■ Version for off-shore 3) or tropicalised application 3)
      ■ Accessories:
        Three-way or five-way valve

 

      3) Inert gas filled contacts required

 

 

     Approvals and certificates
      ■ GOST-R certificate
      ■ Test certificate *CA* (confirmation of the switching accuracy)
      ■ Test report *CP* (3-time listing of the switch point, requires switch point specification)
      ■ Material certificate 3.1 per EN 10204

 

     

     Ordering information
      Model / Switch contacts with version / Setting range / 2 x Process connection / Electrical connection / Switch point(s) / Switching direction(s) / Options
    

      Example: DA10 - U1 - 0/16 mbar - 2 x 1/4" NPT-F - 1/2" NPT-F

 

 

 

 

关键词:压力开关

感兴趣的产品PRODUCTS YOU ARE INTERESTED IN

环保在线 设计制作,未经允许翻录必究 .      Copyright(C) 2021 https://www.hbzhan.com,All rights reserved.

以上信息由企业自行提供,信息内容的真实性、准确性和合法性由相关企业负责,环保在线对此不承担任何保证责任。 温馨提示:为规避购买风险,建议您在购买产品前务必确认供应商资质及产品质量。

会员登录

×

请输入账号

请输入密码

=

请输验证码

收藏该商铺

登录 后再收藏

提示

您的留言已提交成功!我们将在第一时间回复您~