 DTX-1800系列软件V2.77更新重要提示,福禄克网络(FLuke Networks)发布福禄克DTX系列测试仪软件固件新版本。update-V2.77.dtx(下载客户索取)DTX-1800系列软件V2.77更新重要提示适用于:DTX-1800、DTX-1200、DTX-LT 

DTX-1800系列软件V2.77更新重要提示在新的版本当中,扩展了标准的选择范围,修复了一些bug,具体有以下几点:
 
DTX CableAnalyzer Release Notes (March 2015)
Changes to DTX Version 2.77 (March 2015) Please update LinkWare PC to Version 9.2

1. Cable / Spec Database Change

Changed generic cable  names to match internationally accepted nomenclatures:

UTP becomes U/UTP
FTP becomes F/UTP
STP becomes S/FTP

Manufacturer cable types updated/added:
 
ALANTEC
AT&T Cabling Systems
CCT Premise
CORNING Cable Systems
DINTEK LAN CABLES
Eurolan
Furukawa
KELine
Linxcom
METZ CONNECTR (BTR)
Nexans
QUBIX
R&M
SOLARIX
VOKA Cable
 
Added ISO/IEC 14763-3:2014
Added TIA 1005 Cat 6A Channel and TIA 1005 Cat 6A Perm. Link limits
Changed TIA Singlemode fiber length limits to 40,000 m
Profinet delay skew changed from 50 ns to 20 ns
Updated  the following laboratory test limits:
 
ISO C6PCable 100m (LA) Insertion Loss curve
ISO C6A Cable Spool (LA) Return Loss curve
ISO C5ePCable 100m (LA) Insertion Loss curve
ISO C6A PCable 100m (LA) Insertion Loss curve
ISO C6A PCable 100m (LA) Return Loss curve
ISO C6A Cable 100m (LA) Return Loss curve
ISO C6A PCable Spool (LA) Return Loss curve
ISO C6 Cable 100m (LA) Insertion Loss curve

2. Bug Fixes


When over writing an existing fiber test result on the same tester, but using a different fiber module, the serial
number and calibration date are not updated - fixed
 
Changes to DTX Version 2.74 (March 2013)
1. Cable / Spec Database Change
 
Added Korean Pre-Deploy Twisted Pair Test Limit
Added LS Cable&System Korean Limits
Updated the following Cable Libraries:

SCHNEIDER ELECTRIC
2. Bug Fixes
 
10GBASE-SR loss limit was incorrect at 2.5 dB for OM1 fiber, corrected to 2.4 dB
10GBASE-SR OM3 limit was a duplicate of OM4, fixed back to the correct loss limit and length
10GBASE-LX4 length was incorrect at 5,000m, changed to 10,000 m
10GBASE-L length was incorrect at 5,000m, changed to 10,000 m
Changes to DTX Version 2.63 (June 2012)
1. Cable / Spec Database Change
 
10GBASE-SR now permits up to 400 m, 2.9 dB loss with OM4 cable per IEEE update
Added 40GBASE-FR, 40GBASE-LR4, 40GBASE-SR4, 100GBASE-ER4, 100GBASE-LR4, 100GBASE-SR10
Added OTDR limits: General Fiber RL -55dB and ISO/IEC 11801-2010 no RL
Japan folder name changed to JIS
Added Resistance as an information only parameter to Cat 6A patch cord test limits
Added  LMR600, RG-213 and RG-214 coax cable types
Added new Korean Fiber Standards
Updated the following Cable Libraries:
DTX-1800系列软件V2.77更新重要提示
ACOME
AMP NETCONNECT
Brand-Rex
Coax
Corning
Draka
FibrainDATA
Infilink
Legrand
Panduit
Schrack Technik
Siemon
Superior Essex
TE Connectivity
DTX-1800系列软件V2.77更新重要提示

全年征稿/资讯合作 联系邮箱:hbzhan@vip.qq.com
版权与免责声明
1、凡本网注明"来源:环保在线"的所有作品,版权均属于环保在线,转载请必须注明环保在线,https://www.hbzhan.com。违反者本网将追究相关法律责任。
2、企业发布的公司新闻、技术文章、资料下载等内容,如涉及侵权、违规遭投诉的,一律由发布企业自行承担责任,本网有权删除内容并追溯责任。
3、本网转载并注明自其它来源的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品来源,并自负版权等法律责任。
4、如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。

深圳市精诚电子仪器有限公司湖南分公司作者

我要投稿
  • 投稿请发送邮件至:(邮件标题请备注“投稿”)hbzhan@vip.qq.com
  • 联系电话0571-87759680
环保行业“互联网+”服务平台
环保在线APP

功能丰富 实时交流

环保在线小程序

订阅获取更多服务

微信公众号

关注我们

抖音

环保在线网

抖音号:hbzhan

打开抖音 搜索页扫一扫

视频号

环保在线

公众号:环保在线

打开微信扫码关注视频号

快手

环保在线

快手ID:2537047074

打开快手 扫一扫关注
意见反馈